mechanical characteristics
| Characteristic | Standard | Unit | Value |
|---|---|---|---|
| Yield stress (+23°C, dry) |
ISO 527-1/-2 DIN 53455 ASTM D 638 |
MPa (N/mm²) | 165 |
| Elongation at break (+23°C, dry) |
ISO 527-1/-2 DIN 53455 ASTM D 638 |
% | 3 |
| Tensile E-modulus (+23°C, dry) |
ISO 527-1/-2 DIN 53455 ASTM D 638 |
MPa (N/mm²) | 10500 |
| Charpy notched impact strength (+23°C, dry) | ISO 179/1eA | kJ/m² | 8.5 |
thermal characteristics
| Characteristic | Standard | Unit | Value |
|---|---|---|---|
| min. Operating temperature (continuous) | °C | -30 | |
| max. service temperature (continuous) | °C | 110 | |
| max. service temperature (short-term) | °C | 160 | |
| Heat deflection temperature HDT/A (1.8 N/mm²) |
ISO 75-1/-2 DIN 53461 ASTM D 648 |
°C | 210 |
combustibility characteristics
| Characteristic | Standard | Unit | Value |
|---|---|---|---|
| UL94 flammability | IEC 60695-11-10 | class | HB |
physical characteristics
| Characteristic | Standard | Unit | Value |
|---|---|---|---|
| Density, Gross density |
ISO 1183 DIN 53479 ASTM D 792 |
g/cm³ | 1.29 |
| Water absorption at saturation (water storage 23°C) |
ISO 62 DIN 53495 ASTM D 570 |
% | 8 |